Portable Data Recorder
The Model 960 is a battery-operated, transient recorder with two transducer
inputs and two angle inputs. It can serve as a portable threaded fastener
laboratory for measuring fastener torque, angle, and clamp load. It is also
ideal for auditing and certifying power tools and hand torque wrenches. The
Model 960 is a cost-effective, versatile, and easy to use recorder and can
collect up to 500 rundowns. Its alphanumeric setup and calibration menus assure
ease of operation. It can be used with rotary torque-angle and clamp force
transducers and other conventional strain gauge transducers.
Applications
Among many possible applications, the Model 960 is designed for the following:
-
Perform torque versus tension verification testing on fasteners and joints to
verify such things as coatings, lubricants, or plating performance
-
Provide fastener torque versus angle signature analysis for clamp force
verification
-
Perform audit, certification, or tool room calibration of power tools and
torque wrenches
-
Perform dynamic monitoring of power tools on the plant floor to determine their
performance capability
-
Certify calibration factors for single spindle nutrunners and tools by
monitoring the reference transducer and tool transducer simultaneously
Statistics
After each rundown the Model 960 updates the statistics including high, within
limits, and low level readings, standard deviation, and Cpk.
Data & Communications
Data and statistics can be printed via the parallel port. Data can be
downloaded to a PC via the serial port for further analysis. Program updates
are uploaded through the serial port.
Real-rime Plotting Capabilities
The Model 960 lets you capture real time and peak readings for torque-angle,
torque-clamp load, or torque-time and immediately display or plot the
following, based on your instrument setup:
-
Torque vs. Time
-
Torque vs. Angle
-
Angle vs. Time
-
Tool RPM vs. Time
-
Torque vs. Clamp Force
-
Torque and Clamp vs. Angle
Model 980 Specifications
-
Torque and Force Input Channels
-
Input Range: ±2.5 mV/V, ±4.5 mV/V, ±10 VDC or user selectable
-
Excitation: 4.5 VDC or 9 VDC (standard), 120 ma max.
-
Resolution: 16-bit
-
Non-linearity: 0.015% max.
-
Frequency Response: 10 kHz
-
Positive Voltage Peak
-
Trap Circuit: 7 ms reset time
-
Peak Threshold: Software Programmable
-
Peak Reset: Manual or software programmable, automatic reset
-
Angle Input Channels
-
Type: Quadrature A/B Track
-
Excitation: 5 VDC
-
Input Frequency: 1 MHz max.
-
Counter Resolution: 32-bit
-
Display
-
Viewing Area: 4.85 x 2.68 inches
-
Resolution: 240 x 128
-
CFL Backlight
-
Battery
-
Indication: Two-stage Battery Low indication
-
Battery Life: 8 Hours maximum, continuous use
-
Charge Time: 2 hours, max.
-
General
-
Temperature Range: 0-70°C
-
Dimensions
-
Width: 9.75 inches
-
Depth: 8.75 inches
-
Height: 2.75 inches
-
Weight: 7.0 lbs.
-
Mating Connectors
-
Channel 1 and Channel 2: DB, 15 pins
-
Parallel Port: DB, 25 pins
-
Serial Port: DB, 9 sockets